Many aluminum castings contain bifilms, which are cracks that lower the mechanical properties and reliability of castings. The current commercial hot isostatic pressing (HIP) process has proven successful in closing porosity but its success in healing bifilms is questionable. This research investigates the effects of different HIP conditions on the reliability of aluminum castings affected by bifilms. Non-HIPed, typical HIPed, and experimentally HIPed A206 castings with bifilms were mechanically tested and microstructurally examined. As a result of HIP, minimum tensile strength increased by nearly a factor of 3, average elongation improved by up to 8 times, and elongations increased from a maximum of 5 to over 18 percent. However, the elongation reliability essentially did not change as a result of HIP, which suggests that healing of bifilms did not occur.
Full paper (PDF)
PDF · 468.52 KB · Document in English
The full paper is available to members of the institute only.
Log in to downloadDetails
AuthorsJ. T. Staley, M. Tiryakioğlu, J. Campbell
Organisation*Chicago Laboratory, USA, ** Robert Morris University, USA, *** The University of Birmingham, UK
Event67th World Foundry Congress
TopicLight alloys
Document languageEnglish
Year2006